This new technical leg design offers you the option to create a new station or to
renovate existing tables. Thanks to its compactness it can act both as a table leg and
as an item next to a table. This AXG** (* represents power) product is completely
autonomous. With a simple three-phase mains input + neutral + earth, it can provide
all the power supply combinations provided in the table below. Supplied assembled
and ready to be connected to 3-phase 400V from mains.
Height of attachment under bench-top: 720 to 830mm
Length: 665mm
Total height: 1050mm (including console).
Maximum width: 250mm
MAIN DC SUPPLY
0 - 270V variable and insulated from the mains by an insulated transformer as specified
by international safety standards for the use of cirect currents. The whole unit
is protected against overloads and short circuits. Rectification is provided by a generously
over-specified Graetz bridge (ripple rate 4%). Voltmeter and ammeter displays.
A magneto-thermal circuit breaker protects this output. A contactor with a control
button gives command start/stop functions, on condition that the autotransformer
output is at 0V. An everlasting indicator light shows that the unit is powered up.
VARIABLE 3-PHASE SUPPLY
0 - 250V variable and insulated from the mains by an insulated transformer as specified
by international safety standards for the use of direct currents. The whole unit
is protected against overloads and short circuits. Voltmeter and ammeter displays.
An On/Off button control. An indicator light shows that the unit is powered up.
0-250V variable by single phase autotransformer protected against overloading
and short circuits. Voltmeter and ammeter displays. An On/Off button control.
An indicator light shows that the unit is powered up.
DC AUXILIARY SUPPLY
Variable by autotransformer and protected against overloading and short circuits.
The voltage range is 0-430V between phases (450V for the 4000VA model).
A thermal magnetic circuit breaker protects this output. A push button contact
performs start/stop switching on condition that the autotransformer is at 0 voltage.
An indicator light shows that the unit is powered up.
Main supplies 1 & 2 can’t work simultaneously
Auxillary supplies 3 & 4 can’t work simultaneously
SINGLE-PHASE AUXILIARY SUPPLY
0-250V variable by single phase autotransformer protected against overloading
and short circuits. Voltmeter and ammeter displays. An On/Off button control.
An indicator light shows that the unit is powered up.
3-PHASE SUPPLY (3 X 400VAC FIXED)
On four terminals, protected, with switch and On/Off button control.
An indicator light shows that the unit is powered up.
4 POWER SOCKETS 230V (2P+E)
4 x power sockets 230V (2P+E), protected, with indicator lights.
EMERGENCY STOP BUTTON
Key controlled in the centre of the console (can be mounted in alternative positions).
It cuts out a single bank without affecting the others. Positive security stop.
PUSH BUTTON
Start/Stop with indicator providing start-up with "memory" function.
An indicator light shows that the unit is powered up.
renovate existing tables. Thanks to its compactness it can act both as a table leg and
as an item next to a table. This AXG** (* represents power) product is completely
autonomous. With a simple three-phase mains input + neutral + earth, it can provide
all the power supply combinations provided in the table below. Supplied assembled
and ready to be connected to 3-phase 400V from mains.
Height of attachment under bench-top: 720 to 830mm
Length: 665mm
Total height: 1050mm (including console).
Maximum width: 250mm
MAIN DC SUPPLY
0 - 270V variable and insulated from the mains by an insulated transformer as specified
by international safety standards for the use of cirect currents. The whole unit
is protected against overloads and short circuits. Rectification is provided by a generously
over-specified Graetz bridge (ripple rate 4%). Voltmeter and ammeter displays.
A magneto-thermal circuit breaker protects this output. A contactor with a control
button gives command start/stop functions, on condition that the autotransformer
output is at 0V. An everlasting indicator light shows that the unit is powered up.
VARIABLE 3-PHASE SUPPLY
0 - 250V variable and insulated from the mains by an insulated transformer as specified
by international safety standards for the use of direct currents. The whole unit
is protected against overloads and short circuits. Voltmeter and ammeter displays.
An On/Off button control. An indicator light shows that the unit is powered up.
0-250V variable by single phase autotransformer protected against overloading
and short circuits. Voltmeter and ammeter displays. An On/Off button control.
An indicator light shows that the unit is powered up.
DC AUXILIARY SUPPLY
Variable by autotransformer and protected against overloading and short circuits.
The voltage range is 0-430V between phases (450V for the 4000VA model).
A thermal magnetic circuit breaker protects this output. A push button contact
performs start/stop switching on condition that the autotransformer is at 0 voltage.
An indicator light shows that the unit is powered up.
Main supplies 1 & 2 can’t work simultaneously
Auxillary supplies 3 & 4 can’t work simultaneously
SINGLE-PHASE AUXILIARY SUPPLY
0-250V variable by single phase autotransformer protected against overloading
and short circuits. Voltmeter and ammeter displays. An On/Off button control.
An indicator light shows that the unit is powered up.
3-PHASE SUPPLY (3 X 400VAC FIXED)
On four terminals, protected, with switch and On/Off button control.
An indicator light shows that the unit is powered up.
4 POWER SOCKETS 230V (2P+E)
4 x power sockets 230V (2P+E), protected, with indicator lights.
EMERGENCY STOP BUTTON
Key controlled in the centre of the console (can be mounted in alternative positions).
It cuts out a single bank without affecting the others. Positive security stop.
PUSH BUTTON
Start/Stop with indicator providing start-up with "memory" function.
An indicator light shows that the unit is powered up.
Eigenschaften
- AXG-40-/ELE