Go Direct Conductivity Probe determines the ionic content of an aqueous solution by measuring its electrical conductivity. It features a built-in temperature sensor to simultaneously read conductivity and temperature. Automatic temperature compensation allows students to calibrate the probe in the lab and then make measurements outdoors without temperature changes affecting data. This temperature compensation can be turned off to perform conductivity studies as a function of temperature.
The Go Direct Conductivity Probe has a range of 0 to 20,000 μS/cm to provide optimal precision in any given range. An alternating current at its electrodes prevents polarization and electrolysis, reducing contamination of solutions. Its ABS-body graphite electrode resists the corrosion typical in metal electrodes.
The Go Direct Conductivity Probe can be used in a variety of experiments:
- Demonstrate diffusion of ions through membranes.
- Investigate the difference between ionic and molecular compounds, strong and weak acids, or ionic compounds that yield different ratios of ions.
- Measure Total Dissolved Solids (TDS)
Specifications
- Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS)
- Accuracy using factory calibration: ±1% of full scale reading (valid for 1 to 10,000 µS/cm)
- Temperature compensation: Automatic from 5 to 35°C, can be turned off
- Temperature range (can be placed in): 0 to 80°C
- Cell constant: 1.0 cm-1
- Resolution: 0.01 µS/cm
- Description: ABS body, parallel carbon (graphite) electrodes
- Dimensions: 12 mm OD and 12 cm length
- Connections: Wireless (Bluetooth) or wired (USB)
The Go Direct Conductivity Probe has a range of 0 to 20,000 μS/cm to provide optimal precision in any given range. An alternating current at its electrodes prevents polarization and electrolysis, reducing contamination of solutions. Its ABS-body graphite electrode resists the corrosion typical in metal electrodes.
The Go Direct Conductivity Probe can be used in a variety of experiments:
- Demonstrate diffusion of ions through membranes.
- Investigate the difference between ionic and molecular compounds, strong and weak acids, or ionic compounds that yield different ratios of ions.
- Measure Total Dissolved Solids (TDS)
Specifications
- Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS)
- Accuracy using factory calibration: ±1% of full scale reading (valid for 1 to 10,000 µS/cm)
- Temperature compensation: Automatic from 5 to 35°C, can be turned off
- Temperature range (can be placed in): 0 to 80°C
- Cell constant: 1.0 cm-1
- Resolution: 0.01 µS/cm
- Description: ABS body, parallel carbon (graphite) electrodes
- Dimensions: 12 mm OD and 12 cm length
- Connections: Wireless (Bluetooth) or wired (USB)
Properties
- 151022
- GDX-CON