SPECIFICATIES:
Functional Specifications
mA measurement
(Measured by clamp) 771/772/773
Resolution and Range: 0 to 20.99 mA
Accuracy: 0.2%+2 counts
Resolution and Range: 21.0 mA to 100.0 mA
Accuracy: 1% + 5 counts
mA measurement
(Measured in series with test jacks) 772/773
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
mA simulate
(Maximum voltage 50 V dc)
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
Voltage source (2 mA maximum drive current) Resolution and Range: 0 to 10.00 V dc
Accuracy: 0.2% + 2counts
Voltatge Mesaure Resolution and Range: 0 to 30.00 V dc
Accuracy: 0.2% + 2counts
Inbegrepen accessoires: Vier AA-alkalinebatterijen (geïnstalleerd)
Draagtas
TL75-meetsnoeren
AC72 afneembare klem
TL940 meetsnoeren met mini-haakjes
Instructieblad
Ophangsysteem met klittenbandriem
Functional Specifications
mA measurement
(Measured by clamp) 771/772/773
Resolution and Range: 0 to 20.99 mA
Accuracy: 0.2%+2 counts
Resolution and Range: 21.0 mA to 100.0 mA
Accuracy: 1% + 5 counts
mA measurement
(Measured in series with test jacks) 772/773
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
mA simulate
(Maximum voltage 50 V dc)
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2counts
Voltage source (2 mA maximum drive current) Resolution and Range: 0 to 10.00 V dc
Accuracy: 0.2% + 2counts
Voltatge Mesaure Resolution and Range: 0 to 30.00 V dc
Accuracy: 0.2% + 2counts
Inbegrepen accessoires: Vier AA-alkalinebatterijen (geïnstalleerd)
Draagtas
TL75-meetsnoeren
AC72 afneembare klem
TL940 meetsnoeren met mini-haakjes
Instructieblad
Ophangsysteem met klittenbandriem
Eigenschappen
- FLUKE 773/FLU